This category covers everything that turns rock in the ground into a defensible number. Consulting geologists do the field and desk work — mapping, core and chip logging, sampling design, database building, resource estimation and the written technical reports that lenders, regulators and buyers actually read. Laboratories do the analysis in two stages: sample preparation (drying, crushing to a nominal fraction, splitting a subsample, then pulverising to a target mesh) and then the analytical method, where fire assay with lead collection and cupellation remains the reference method for gold and silver at ore grades, while inductively coupled plasma methods — ICP-AES/OES for higher concentrations and ICP-MS for trace levels, after either a partial (aqua regia) or near-total (four-acid) digestion — cover the multi-element suite. Metallurgical test work is a separate discipline that takes a representative composite and measures how the rock behaves in a plant: comminution and grindability, gravity, flotation, leach recovery, reagent consumption and deleterious elements. Wrapping all of it is QA/QC (certified reference materials, blanks, field and pulp duplicates, umpire assays at a second lab, chain of custody) and physical core management — logging facilities, photography, cutting, boxing, labelling and long-term storage — because core and pulps are samples of record that you will be asked to re-examine years later.
20 firms working in this trade
Alphabetical. Nobody paid to be here
- American Assay LaboratoriesSparks, Nevada
Gold analysis, geochemistry, ICP-MS, XRF and sample preparation
aallabs.com - Global Resource EngineeringGolden, Colorado
Geology mapping and modeling, resource and reserve estimation
global-resource-eng.com - Gustavson AssociatesBoulder, Colorado
Exploration geology, resource and reserve evaluation, mineral appraisal
gustavson.com - Hard Rock ConsultingAurora, Colorado
Technical services for mineral resource projects, prospect through closure
hardrock-consulting.com - Hazen ResearchGolden, Colorado
Process mineralogy, mineral beneficiation, hydrometallurgy and analytical chemistry
hazenresearch.com - Independent Mining ConsultantsTucson, Arizona
Resource and reserve modeling, mine planning and feasibility studies
imctucson.com - Itasca Consulting GroupMinneapolis, Minnesota
Rock mechanics, microseismic monitoring and slope stability analysis for mines
itascacg.com - John T. Boyd CompanyCanonsburg, Pennsylvania
Geologic modeling, resource and reserve evaluation, exploration and reporting
jtboyd.com - Kappes, Cassiday & AssociatesReno, Nevada
Metallurgical testing for gold, silver and base metal ores
kcareno.com - Marshall Miller & AssociatesBluefield, Virginia
Geological, hydrogeological and mining engineering services, wireline geophysics
mma1.com - McClelland LaboratoriesSparks, Nevada
Metallurgical testing, leach and flotation testwork, fire assay
mettest.com - Metallogeny, Inc.Fairbanks, Alaska
Exploration staffing, soil and rock sampling, drill program management
metallogeny.com - Paragon GeochemicalSparks, Nevada
Sample preparation, fire assay, PhotonAssay and geochemical analysis
paragongeochem.com - Rangefront Mining ServicesElko, Nevada
Contract geologists, soil and rock chip sampling, 3D modeling
rangefront.com - RESPECRapid City, South Dakota
Geoscience, geophysics, geochemistry and 3D modeling for exploration
respec.com - SGSBloomfield, New Jersey
Lead collection fire assay for gold and platinum group elements
sgs.com - SRK ConsultingReno, Nevada
Geological investigation, geochemical characterization, resource and reserve estimation
srk.com - Standard Laboratories, Inc.Scott Depot, West Virginia
Coal and fuel sampling and testing, ISO 17025 laboratories
standardlabs.com - Telesto SolutionsLoveland, Colorado
Natural resources, water resources and permitting for mining projects
telestoinc.com - Western Environmental Testing LaboratorySparks, Nevada
Water, soil and mine waste characterization analysis
wetlaboratory.com
Listed because we found them, not because they asked or paid. Every entry was checked against the company’s own website; none of it is an endorsement, and we have no commercial relationship with anyone on this page. Work in Geology, assay and laboratory and want to be added, corrected or removed? Tell us — it is free either way.
The methods, and when each is used
What each technique is for, what defines it, and where it fails
Fire assay with gravimetric finish
The classical, and still the referee, method for gold and silver. The sample is fused with a lead-bearing flux so that the precious metals are collected into a lead button, the lead is oxidised away in a bone-ash cupel, and the remaining precious-metal bead is weighed directly on a microbalance. Used for high grades, for bullion, and wherever an absolute mass is wanted rather than an instrument response.
Specification, and where it falls down
Specificationmeasures the metal itself, by mass. The sample charge is defined by the assay ton: a weight chosen 'so each milligram of a noble metal in the sample is equivalent to one troy ounce in one avoirdupois ton (2000 lb) of ore' — 29.167 g in North America, 32.667 g where the long ton is used. USGS Bulletin 1445 tabulates flux charges for a 15 g sample - sodium carbonate, litharge (PbO), silica, borax glass, calcium fluoride, flour as reductant and potassium nitrate as an oxidant for sulphide ores - with the quantities varying by ore type; the table should be read in the source rather than reduced to a single set of ranges here. Fusion: furnace at 1000 degrees C, down to 900 degrees C for about 17 minutes, then back to 1000 degrees C for a further 15 minutes. Cupellation for gold with a silver collector runs from 820 degrees C to 880 degrees C. USGS takes the gravimetric route 'when bead weight exceeds 20 milligrams', with gold and silver then separated by parting in nitric acid.
Where it falls downOnly practical at high concentrations: USGS takes the gravimetric route only when the bead exceeds 20 mg, and below that the bead is too small to weigh accurately, which is why almost all exploration gold is finished instrumentally instead. Silver and palladium are partly lost into the cupel and into the slag; gold is the best behaved of the noble metals in a lead collection, which is exactly why lead fire assay is not used alone for the full platinum-group suite. Fire assay collects 'Ag, Au, Ir, Os, Pd, Pt, Rh, Ru' while 'eliminating virtually all the associated gangue minerals', but recovery of iridium, osmium and ruthenium into a lead button is poor. It says nothing about how the gold occurs, and a 15 g or 30 g charge is a very small sample of a coarse-gold rock.
sourceFire assay with AAS or ICP finish
The standard production gold assay. The fire assay front end is identical — flux fusion, lead button, cupellation — but the resulting bead is dissolved in acid and measured on an instrument instead of being weighed. This is what almost every gold drill assay in the United States actually is.
Specification, and where it falls down
Specificationmeasures gold (and silver, platinum, palladium) after physical pre-concentration, which is why its detection limits beat any direct digestion. A USGS field-study method (Open-File Report 2007-1126) using a 10 g charge with a dore bead and AA finish reports a gold detection limit of 0.002 ppm (2 ppb). A USGS fire-assay-plus-ICP-MS package for Au, Pt and Pd gives detection limits of 1 ppb for gold and palladium and 0.5 ppb for platinum. Typical laboratory charges are 30 g (approximately one assay ton) or 50 g.
Where it falls downEverything the fire assay front end misses, it still misses — and now the small instrument detection limit creates false confidence in a number whose real uncertainty is set by the 30 g charge, not by the instrument. High-grade samples exceed the calibrated range and must be re-run by a gravimetric or ore-grade method. For coarse-gold material a single 30 g charge is simply too small a subsample, which is the entire reason screen fire assay exists.
sourceScreen fire assay (metallic screen assay) for coarse gold
The correct assay when gold occurs as visible or coarse grains, where a routine 30 g charge is a lottery ticket. A large pulp is screened at a fine aperture; the entire coarse (oversize) fraction is assayed as one, the fine (undersize) fraction is assayed in duplicate, and a weighted average is computed from the two masses.
Specification, and where it falls down
Specificationmeasures the whole coarse gold population instead of hoping to catch a representative share of it. A Spectroscopy Europe sampling column by Dominy, Purevgerel and Esbensen - a trade-magazine column rather than a peer-reviewed paper - describes the route as 'a total sample preparation and screen fire assay route', with pulp quality specified as '95 % to be P95 75 micrometres' - that is, 95% of pulps are required to achieve 95% passing 75 micrometres - and notes that for screen fire assay 'a high precision would be expected for undersize fraction' because all the coarse gold has been removed from it. The same work shows the field split being increased 'up from 2 kg to 4 kg' to address coarse gold, targeting 'a theoretical sample support of 3 kg m-1'. note: the common commercial configuration (approximately 1 kg pulp screened at 100 mesh / 150 micrometres, oversize assayed in total, undersize assayed in duplicate) is laboratory practice described only in commercial laboratory literature; it is widespread convention, not a published standard, and the specific mesh and mass are therefore not asserted here.
Where it falls downExpensive and slow, so it is applied selectively rather than to every sample, which introduces a selection decision that must itself be defensible. It fixes the subsampling error at the pulp stage but does nothing about the far larger error introduced earlier: sampling studies find 'a large component of the total error is introduced during sample collection, especially during primary sampling', with the field relative sampling variability in the two case studies reported reaching 42% and 34%. It also cannot fix a field sample that was too small to contain a representative number of gold grains in the first place.
sourceAqua regia digestion
A hot 3:1 hydrochloric/nitric acid attack used for cheap, high-throughput multi-element exploration geochemistry — soils, stream sediments, and base-metal ores. It is the default partial digestion, chosen because it dissolves sulphides, carbonates, most oxides and organically bound metals well, and silicates hardly at all.
Specification, and where it falls down
Specificationdissolves sulphides, sulphosalts, carbonates, many oxides, and metals adsorbed on clays and organic matter. does not dissolve the silicate lattice. Commercial ore-grade multi-element packages use a charge of a few tenths of a gram at a 3:1 HCl:HNO3 ratio and describe the attack as a partial digestion from which chromite, zircon and rutile are not dissolved; that description is commercial laboratory method text, no government or standards-body source giving the charge mass could be opened for this page, and neither is quoted here as though published. The closely related EPA Method 3050B nitric acid / hydrogen peroxide digestion, which is the source linked below and is not itself an aqua regia method, makes the same point in the clearest published language: 'this method is not a total digestion technique for most samples. It is a very strong acid digestion that will dissolve almost all elements that could become environmentally available', deliberately leaving silicate-bound elements undissolved; it uses 1-2 g wet or 1 g dry sample at 95 +/- 5 degrees C.
Where it falls downunder-reports, sometimes badly. Aluminium, potassium, titanium, zirconium, hafnium, chromium, barium, tin, tungsten, niobium, tantalum and the rare earths are all reported low, because the minerals that host them — feldspar, mica, zircon, rutile, chromite, barite, cassiterite, monazite — survive the acid. Volatile elements can be lost during digestion. Results are not comparable with four-acid or fusion results and must never be mixed in one dataset without a conversion study.
sourceFour-acid near-total digestion
The standard multi-element digestion for ore and rock: hydrochloric, nitric, perchloric and hydrofluoric acids in sequence. The hydrofluoric acid is the point of it — HF breaks the Si-O bond and destroys the silicate lattice that aqua regia leaves intact, so the result approaches a whole-rock composition.
Specification, and where it falls down
Specificationdissolves essentially all silicates, sulphides, carbonates and most oxides. A USGS 42-element package (Open-File Report 2006-1070) uses 0.25 g of sample in 'a mixture of hydrochloric, nitric, perchloric, and hydrofluoric acids at low temperature', reporting major elements (Al, Ca, Fe, K, Mg, Na, Ti) to a lower limit of 0.01%, arsenic and silver to 1 ppm; a companion USGS 40-element four-acid package (Open-File Report 2007-1126, 0.2 g charge) sets acceptance criteria of plus or minus 15 percent recovery and duplicate RSD no greater than 15 percent. The equivalent EPA microwave total-decomposition method uses about 0.5 g in '9 mL of concentrated nitric acid and usually 3 mL hydrofluoric acid', ramped to '180 +/- 5 degrees C in approximately 5.5 minutes' and held there for 9.5 minutes.
Where it falls down'near-total' is a load-bearing word. EPA's total-decomposition method states the constraint in published form: 'a few refractory sample matrix compounds, such as TiO2, alumina, and other oxides may not be totally dissolved', and those resistant grains 'might sequester target analyte elements'. In practice zircon, chromite, spinel, rutile, cassiterite, monazite, barite and tourmaline resist the attack, so zirconium, hafnium, chromium, tin, niobium, tantalum, barium, titanium and some rare earths come back low. Barium needs separate care, but not for the reason often given: perchloric acid supplies no sulphate and barium perchlorate is soluble. Where the sample carries sulphur, oxidative digestion converts it to sulphate and precipitates barium as insoluble BaSO4; where it does not, a low barium result simply reflects undissolved barite. Either way the control is mineralogy. If those elements matter — for lithogeochemistry, for tracing, for a critical-minerals assessment — the correct method is a fusion, not a stronger acid.
sourceSodium peroxide fusion or sinter
A strongly oxidising alkaline fusion that dissolves the minerals acid cannot touch. The sample is heated with sodium peroxide until it decomposes completely, then the melt or sinter is taken up in water and acidified. Used where refractory hosts are present or where a genuinely total result is required — chromite, zircon, tourmaline, cassiterite, tantalum and niobium minerals, and high-sulphide ores.
Specification, and where it falls down
Specificationdissolves effectively everything, including the resistant accessory minerals that four-acid leaves behind. A USGS 55-element package uses 'a sodium peroxide sinter at 450 degrees C' followed by water leaching and nitric acid acidification, determining 55 elements including the full rare earth suite, with major elements reported in weight percent and traces in ppm. The low sinter temperature (450 degrees C, versus a full melt at higher temperature) is chosen to limit crucible attack and blank contribution.
Where it falls downThe flux is the problem. A large mass of sodium peroxide is added to a small mass of sample, so the dissolved solids load is high, the dilution is large, and detection limits are correspondingly worse than an acid digestion for the same element. Sodium and any element present in the flux or crucible become unmeasurable or unreliable. Zirconium and nickel crucibles each contaminate the solution with their own metal. Sulphur is oxidised to sulphate and lost to the method as a speciated measurement. It is a specialist, higher-cost route, not a routine replacement for four-acid.
sourceLithium borate fusion
The standard whole-rock preparation: the sample is fused with lithium metaborate or tetraborate at high temperature into a homogeneous glass, which is then either cast as a disc and read directly by XRF, or dissolved in dilute acid and run on ICP. The reference method for major-element chemistry and for resistant-mineral-hosted trace elements.
Specification, and where it falls down
Specificationdissolves the whole sample, including zircon, rutile, monazite and the other acid-resistant accessories, and is a true total decomposition for silicate rocks. Chromite is the known exception: it dissolves incongruently in lithium tetraborate flux (Merkle, X-Ray Spectrometry 33, 2004), which is why chrome-bearing material goes to a peroxide fusion instead. The only open USGS fusion-XRF procedure available for this page is written for coal ash rather than whole rock, and its figures should be read with that scope in mind. It uses '600 mg of coal ash with 5.400 g of lithium tetraborate', a roughly 1:9 sample-to-flux ratio, fused for '20 minutes at 1,100-1,200 degrees C' or 'one hour at 1,100 degrees C' in a furnace, with a few drops of dilute hydrobromic acid as a non-wetting agent, cast into platinum-gold moulds as glass discs. Eleven major and minor elements (Na, Mg, Al, Si, P, S, K, Ca, Ti, Mn, Fe) are determined with detection limits 'as low as 1 microgram per gram for elements having atomic numbers greater than 26', rising to 'several hundred micrograms per gram for aluminum and silicon' and 'several thousand micrograms per gram for sodium'; precision is '2 to 5 percent for coal ash and 10 percent for determinations of elements in the whole coal'.
Where it falls downVolatile elements are lost in the melt — sulphur, chlorine, mercury, arsenic, antimony, selenium and cadmium cannot be determined on a fused bead, and the USGS procedure warns that the higher temperature produced by a Meeker burner in a Claisse fluxer may volatilise sodium from certain samples. The heavy flux dilution raises detection limits, making the method poor for low-level trace work. Sulphide-rich and metal-rich samples attack platinum crucibles and are often unsuitable without pre-roasting. USGS also identifies a practical constraint that has nothing to do with chemistry: 'the most important factor limiting the accuracy of analysis is the restricted availability of standard reference materials'.
sourceICP-OES (inductively coupled plasma optical emission spectrometry)
The multi-element workhorse for solutions at ppm level and above. The digest is nebulised into an argon plasma at several thousand kelvin; every element emits light at its own characteristic wavelengths, and the intensities are read simultaneously. The routine finish for four-acid and aqua regia ore-grade packages.
Specification, and where it falls down
Specificationmeasures emitted light intensity at element-specific wavelengths, in solution — so it measures only what the digestion put into solution, and nothing else. EPA's method covers 31 elements in aqueous solutions and waste digests. It is deliberate about detection limits: 'IDLs are necessarily instrument-specific' and must be established in each laboratory as 'the mean of the blank results plus three times the standard deviation of 10 replicate analyses'. In geological use, a USGS four-acid ICP package reports major elements at 0.01% and elements such as arsenic and silver at 1 ppm.
Where it falls downFour interference classes are recognised: spectral (line overlaps and background emission), physical (viscosity and surface tension effects from high dissolved solids), chemical (molecular compound formation, ionisation and solute vaporisation effects) and memory (carry-over from a previous sample). Dynamic range at the low end is limited — for many trace elements ICP-OES simply cannot reach the concentrations exploration geochemistry needs, which is why ICP-MS exists. High total dissolved solids from a fusion degrade both precision and detection limits. And the cardinal limitation is not the instrument at all: an ICP-OES result on an aqua regia digest reports what aqua regia dissolved, not what the rock contains.
sourceICP-MS (inductively coupled plasma mass spectrometry)
The same plasma, but ions are extracted into a mass spectrometer and counted by mass-to-charge ratio rather than measured by emitted light. Two to three orders of magnitude more sensitive than ICP-OES, and the only practical route to sub-ppm rare earths, platinum-group elements and low-level pathfinder elements.
Specification, and where it falls down
Specificationmeasures ion counts at specific mass-to-charge ratios in solution. EPA's method applies to 'determination of sub-microgram/L concentrations of a large number of elements in water samples and in waste extracts or digests', validated through multi-laboratory testing for 23 listed elements, though the method notes that 'ICP-MS has been applied to the determination of over 60 elements in various matrices'; instrument detection limits 'will generally be < 0.1 microgram/L' in simple matrices, though 'for less sensitive elements (e.g. Se and As). IDLs may be >= 1.0 microgram/L'. In geological application a USGS fire-assay ICP-MS package reaches 1 ppb for gold and palladium and 0.5 ppb for platinum; a USGS sodium-peroxide-sinter ICP-MS package covers 55 elements including the full rare earth suite.
Where it falls downFour interference classes are specified: isobaric elemental (two elements producing ions at the same mass, requiring isotopic correction), molecular/polyatomic (multi-atom ions such as ArCl+ and MoO+ that land on analyte masses — the classic case is 40Ar35Cl+ on 75As, which is why arsenic in a chloride-rich digest needs care), ion current tailing from an intense signal at an adjacent mass, and physical (matrix effects on nebulisation and ion transmission, handled by internal standardisation or dilution); memory and carry-over between samples are treated separately again. High dissolved solids suppress signal and clog the interface, so fusion digests must be heavily diluted, which erodes the sensitivity advantage. Ore-grade samples saturate the detector and must be re-run diluted or by another method.
sourceAAS (atomic absorption spectrometry) — flame, graphite furnace and cold vapour
A single-element technique in which light from a lamp specific to one element passes through an atomised sample and the absorption is measured. Displaced from routine multi-element work by ICP, it survives for specific jobs: the finish on a fire assay bead, mercury by cold vapour, and high-precision single-element determinations.
Specification, and where it falls down
Specificationmeasures absorption of element-specific light by free atoms. EPA's flame method covers 25 elements from aluminium to zinc in 'ground water, aqueous samples, extracts, industrial wastes, soils, sludges, sediments, and similar wastes', all solids requiring digestion first; example lower limits of quantitation in reagent water are magnesium 0.001 mg/L, sodium and lithium 0.002 mg/L, beryllium, cadmium and zinc 0.005 mg/L, calcium 0.01 mg/L and copper 0.02 mg/L, with EPA stressing these are 'guidance purposes only'. For mercury, USGS cold-vapour AAS on a 0.1 g charge gives a detection limit of 0.006 ppm; a USGS regional package using nitric/hydrochloric digestion and cold-vapour AAS reports mercury to 0.02 ppm. Tellurium by flame AA on a 2.0 g charge is reported to 0.1 ppm.
Where it falls downOne element at a time, so multi-element work is slow and expensive. Chemical interference occurs where atoms stay bound in molecules because the flame is too cool — phosphate suppresses magnesium, calcium and barium unless lanthanum is added. Spectral interference from other elements' absorption lines can be reduced by narrowing the slit. High dissolved solids cause light scattering (background interference), and hot flames cause ionisation, suppressed by adding 1,000 mg/L of an easily ionised element such as potassium, sodium, lithium or caesium. Flame AAS has a narrow working range and poor sensitivity compared with ICP-MS.
sourceXRF — portable and laboratory
Irradiates the sample with X-rays and measures the characteristic fluorescent X-rays each element emits. Requires no digestion at all, which is its great strength and the source of all its limitations. Portable units give an on-the-spot reading on core, chips or soil; laboratory wavelength-dispersive instruments on fused beads give high-precision major-element chemistry.
Specification, and where it falls down
Specificationmeasures elements in the solid, non-destructively — nothing is dissolved, so there is no digestion bias, but also no pre-concentration. EPA's field-portable method covers 26 elements in soil and sediment and gives example lower limits of detection in clean quartz sand with count times of 100-600 seconds: lead 20 mg/kg, barium 20 mg/kg, chromium 150 mg/kg, cadmium 100 mg/kg — with the explicit caveat that these vary greatly with matrix, instrument and conditions. Intrusive (prepared-sample) analysis requires homogenisation, drying 2-4 hours at under 150 degrees C, grinding and sieving to 60 mesh; 'microwave drying is not a recommended procedure'. The laboratory fused-bead route, for which the published USGS example is written for coal ash, uses a roughly 1:9 sample-to-flux lithium tetraborate fusion at 1,100-1,200 degrees C and achieves 2-5% precision on major elements.
Where it falls downPoor to blind on light elements: EPA Method 6200 states that 'generally elements of atomic number 16 or greater can be detected and quantitated by FPXRF', which leaves out aluminium (13), silicon (14) and phosphorus (15). That method dates from 1998 and detectors have since improved, so treat the cut-off as method-specific rather than a law of the instrument. Detection limits are far too high for gold and most precious-metal exploration. Matrix effects are severe — large vanadium concentrations interfere with chromium measurement and iron interferes with cobalt quantitation, because the interfering lines sit within a few tens to a couple of hundred electron volts of the analyte lines, and where lead exceeds arsenic by a factor of ten the arsenic result is unreliable and EPA advises that 'all critical soil samples be sent off site for confirmatory analysis'. Moisture between 5 and 20% causes minimal error but saturated samples do not work. The single biggest control on data quality is sample preparation, not the instrument: EPA states 'homogenisation is the most critical factor when comparing the results'. In situ readings sample only the few millimetres of material facing the window.
sourceCombustion infrared analysis for carbon and sulphur
Burns the sample in flowing oxygen in an induction or resistance furnace and measures the CO2 and SO2 produced with solid-state infrared detectors. It is the standard determination of total carbon and total sulphur in rock, soil, coal and ore — the inputs to acid-generation prediction, carbonate accounting and organic-carbon estimation.
Specification, and where it falls down
Specificationmeasures total carbon and total sulphur, converted to gas. USGS total carbon: 'approximately 0.20 g' of sample (0.100 g above 10% C), combusted at 1350 degrees C, CO2 'measured by a solid state infrared detector', working range 0.05% to about 50%, limit of detection 0.03% and lower limit of determination 0.05%, with duplicate RSD of about 1% over 0.23 to 49.0% C. USGS total sulphur: 'approximately 0.25 g sample. mixed with 1 g vanadium pentoxide flux', 1350 degrees C, SO2 by infrared detector, working range 0.05% to about 35%, lower limit of detection 0.0004% and lower limit of determination 0.0007%, mean duplicate RSD 3% over 0.05 to 32%. ASTM D4239 covers sulphur in coal and coke 'by high-temperature tube furnace combustion'.
Where it falls downIt measures total carbon and total sulphur, and nothing else — it cannot tell carbonate carbon from organic carbon, or sulphide sulphur from sulphate sulphur. Those splits require separate determinations (acid leach then re-combustion, or coulometric titration of carbonate carbon, reported by USGS with limits of 0.01-50%). Interferences are specific and real: 'high concentrations of fluorine and molybdenum will interfere with the detection of CO2 by coating the cell walls and the detector', with samples above 0.2% fluorine or 1% molybdenum requiring reduced sample weights. Organic-rich material can combust too fast for the detector unless a retardant is added.
sourceThe protocols that decide whether a result is trustworthy
The procedures between a sample and a number you can rely on
Sample preparation: crush, split, pulverise
The staged reduction of a several-kilogram field sample to a 30-50 g analytical charge. Every stage discards material, and every discard is a chance to throw away the part of the sample that mattered. More error enters most datasets here than at the instrument.
What the procedure actually requires
The USGS rock preparation procedure: break large pieces to 'approximately 2 1/2" x 2"', jaw-crush to chips, split with a riffle splitter having '1/2" riffles' where the mass must be reduced, then pulverise in a ceramic-plate vertical pulveriser to 'approximately minus 100-mesh (<150 micrometres)', with the acceptance criterion that '100 percent passes an 80-mesh screen (<180 micrometres) and at least 80 percent passes a 100-mesh screen (<150 micrometres)'. Contamination control is part of the procedure, not an afterthought: cleaning between samples, and for sensitive work, 'a small quantity of quartzite gravel should be crushed before crushing each sample to clean the apparatus'. A USGS field study describes the same route: 'crushed in a jaw crusher, then ground in a vertical pulverizer with ceramic plates to less than 100 mesh (less than 150 microns)'. In the mineral industry the widely used pulverising specification is 85% passing 75 micrometres, and sampling work on gold specifies a tighter '95 % to be P95 75 micrometres'. The West Virginia DEP Geology Handbook - a state surface coal mining regulatory handbook covering coal-overburden sampling, not a general rock-preparation standard - specifies drying at 40 degrees C and crushing 'with a jaw crusher to less than 1/4-inch mesh' at the coarse stage. On subsample mass, a paper on platinum-group-element practice in the Journal of the Southern African Institute of Mining and Metallurgy (Lomberg, 2014) urges using 'as much sample as possible for fire assay' and recommends a 50 g aliquot wherever possible, giving half-core sample masses for PGE reefs of 230-420 g for BQ core and 410-710 g for NQ core. note: the 85% passing 75 micrometres figure and the 'crush 70% passing 2 mm' style specifications are industry convention set by laboratory service schedules, not published standards.
sourceCertified reference materials (CRMs / standards)
Pre-prepared pulps of known, certified grade, inserted into the sample stream disguised as ordinary samples. They are the only direct test of whether the laboratory's numbers are accurate, and the only way to detect a calibration drift after the fact.
What the procedure actually requires
A review of quality-control practice in mineral exploration reports that 'a 20% control-sample insertion rate has practically become an industry standard', with a core-drilling breakdown of standards/SRMs 6%, coarse duplicates 2%, pulp duplicates 2%, twin samples 2%, coarse blanks 2%, pulp blanks 2% and check samples 4%. It recommends 'at least three different SRMs for the most economically important elements', spanning a low grade near the cut-off, a medium grade near the deposit average, and a high grade around the 95th percentile, and states that control limits for SRM assessment are 'usually at plus/minus three standard deviations'. A paper on platinum-group-element practice in the Journal of the Southern African Institute of Mining and Metallurgy (Lomberg, 2014) recommends inserting 'two different certified reference materials (CRMs), a blank, and a duplicate within every 20 samples submitted', which gives '5% coverage for each of the control sample types'. CIM's guidelines, which are advisory Canadian guidance under NI 43-101 and not binding on a US operator, say only that 'blanks and certified reference material samples should be included in the sample set frequently enough to provide statistical confidence' — it deliberately sets no percentage. So: the 5% per control type and the +/-2 or +/-3 standard deviation acceptance windows are entrenched convention, not a rule. Reference-material producers are accredited to ISO 17034 and testing laboratories to ISO/IEC 17025; SEC rules require disclosure of 'whether the laboratories are certified by any standards association'. The scale of the problem is documented: across 46 audited projects from 2007-2010, only 31% of QA/QC programmes rated acceptable or better.
sourceBlanks
Material known to contain essentially none of the element of interest, inserted into the stream to detect contamination. A coarse blank (barren rock) is inserted before crushing and tests the whole preparation chain; a pulp blank is inserted at the laboratory and tests only the analytical stage.
What the procedure actually requires
Typical insertion is 2% coarse blanks and 2% pulp blanks within a 20% total control-sample rate, or one blank in every 20 samples (5%) under precious-metals guidance. The diagnostic value is in where the blank is placed: a coarse blank inserted immediately after a high-grade sample tests whether the crusher and pulveriser are carrying material over between samples, which is the commonest preparation failure. CIM's guidelines, advisory Canadian guidance under NI 43-101 and not binding on a US operator, say that 'blanks and certified reference material samples should be included in the sample set frequently enough to provide statistical confidence' without setting a rate. A blank result is judged against the method's detection limit, which EPA defines formally - in 40 CFR Part 136 Appendix B, a Clean Water Act wastewater rule rather than a mining or SW-846 standard - as 'the minimum measured concentration of a substance that can be reported with 99% confidence that the measured concentration is distinguishable from method blank results', established from at least seven spiked samples and seven method blanks run in at least three batches on three different dates.
sourceField, coarse-reject and pulp duplicates
Three nested repeat samples that isolate where the variability comes from. A field duplicate (a second half or quarter of the same core interval, or a second split of the same RC interval) measures total error including the geology. A coarse-reject duplicate, split after crushing, measures preparation error. A pulp duplicate, split after pulverising, measures analytical error alone.
What the procedure actually requires
Recommended insertion is 1 in 20 (5%) for each of field duplicates, coarse reject duplicates and pulp duplicates under sampling-theory guidance for gold; a broader practice review gives 2% each for coarse duplicates, pulp duplicates and twin samples within a 20% total. Precision is typically assessed with the half absolute relative difference (hard) statistic, with a performance indicator for fine gold field duplicates quoted as '90 % +/- 10-25 % hard' — that is, 90% of pairs within that band. The expected ordering is diagnostic: pulp duplicates should be tightest, coarse duplicates intermediate, field duplicates widest. If field and pulp duplicates scatter similarly, the sample is too small. CIM's guidelines, advisory Canadian guidance under NI 43-101 and not binding on a US operator, recommend 'unbiased splitting procedures to obtain representative subsamples' that are 'tested, verified, and then applied'. The specific hard thresholds are convention drawn from sampling theory practice, not a published standard.
sourceUmpire (check / referee) assaying
Sending a subset of pulps already assayed by the primary laboratory to a second, independent laboratory. It is the only control that can detect a bias affecting the primary laboratory as a whole — a bias that CRMs from the same supplier, run in the same laboratory, will not reveal.
What the procedure actually requires
A paper on platinum-group-element practice in the Journal of the Southern African Institute of Mining and Metallurgy (Lomberg, 2014) recommends submitting pulps to an independent laboratory at '1 in 10 (10%)' frequency for comparative assay verification; the broader practice review allocates 4% to check samples within the 20% total. CIM's guidelines, advisory Canadian guidance under NI 43-101 and not binding on a US operator, recommend 'regular check sampling by a third-party analytical laboratory' together with periodic 'audits of the methods and procedures used by the primary assay laboratory'. Results are compared pair by pair and as a population — a consistent offset across the whole set is a bias and must be resolved before the data are used, typically by a third referee laboratory. SEC rules require the qualified person to state 'the nature, extent, and results of quality control procedures and quality assurance actions taken' and to give an opinion on the 'adequacy of sample preparation, security, and analytical procedures'. The 5-10% umpire rate is convention.
sourceChain of custody and sample security
The documented, unbroken record of who held each sample, when, and where, from the moment it is cut from the core until the pulp is archived. Its purpose is not bureaucratic: it is what makes salting, substitution and accidental mix-up detectable rather than invisible.
What the procedure actually requires
CIM's guidelines, advisory Canadian guidance under NI 43-101 and not binding on a US operator, state that 'a geoscientist should supervise the sample collection and ensure that a chain of custody of the samples is established and recorded'. The West Virginia DEP Geology Handbook, a state surface coal mining regulatory handbook, defines the mechanism: 'a chain of custody provides a simple method to track the geologic samples, from the time of collection through the time the sample is analyzed', recording 'date and time, along with the identity of such samples', with each sample label carrying at minimum the site or project name, drill hole number, drilling date and the sampling interval or identification number. SEC rules require registrants to describe sample preparation methods and quality control measures including 'sample splitting and reduction methods, and the security measures taken to ensure the validity and integrity of samples', to state whether the laboratories are certified, and to justify any use of non-conventional industry procedures. Sealed, numbered bags, tamper-evident closures, controlled sample numbering that does not reveal expected grade, and secure storage of coarse rejects and pulps are standard practice rather than published requirements.
sourceSpecifications worth knowing
Technical figures, each linked to the document it came from
- 29.167 g (North America) / 32.667 g (long ton)The assay tonne — the fire assay sample mass at which one milligram of recovered metal equals one troy ounce per ton of ore. The routine 30 g charge is essentially one assay tonne.source
- Gold 1 ppb, palladium 1 ppb, platinum 0.5 ppb (fire assay + ICP-MS); gold 0.002 ppm (10 g charge, AA finish)Published USGS lower reporting limits for gold and platinum-group elements by fire assay with an instrumental finish. The 1 ppb and 0.5 ppb ICP-MS limits are from the report linked below; the 0.002 ppm AA limit is from USGS Open-File Report 2007-1126.source
- Lead 20 mg/kg, barium 20 mg/kg, chromium 150 mg/kg, cadmium 100 mg/kg (100-600 second count, clean quartz sand)Example portable XRF lower limits of detection from EPA's method — orders of magnitude above laboratory digestion methods, and only achieved in a clean matrix with long counting.source
- 100% passing 80 mesh (<180 micrometres), at least 80% passing 100 mesh (<150 micrometres); riffle splitter with ½ inch riffles; jaw-crush feed broken to about 2½ x 2 inchesThe USGS rock sample preparation acceptance specification — the published, citable version of what a laboratory preparation schedule is doing. The mineral industry's common 85% passing 75 micrometres is a tighter convention, not a standard.source
- 20% total control-sample insertion: standards 6%, check samples 4%, coarse duplicates 2%, pulp duplicates 2%, twin samples 2%, coarse blanks 2%, pulp blanks 2%The industry-convention QA/QC insertion budget for core drilling, from a published review of exploration quality-control practice. Alternative convention: 1 in 20 (5%) each for CRMs, blanks and duplicates, with umpire checks at 1 in 10.source
- 0.2 g (four-acid ICP-AES); 0.5 g (microwave HNO3/HF total); 0.20 g carbon; 0.25 g sulphur with 1 g vanadium pentoxide; 0.1 g mercury; 2.0 g tellurium; 600 mg with 5.400 g lithium tetraborate for fusion XRFAnalytical charge masses by method. They are small - which is why everything upstream of the balance has to be right. The 0.2 g four-acid ICP-AES, 0.1 g mercury and 2.0 g tellurium charges are from USGS Open-File Report 2007-1126, linked below; the 0.5 g microwave HNO3/HF charge is from EPA Method 3052; the 0.20 g carbon and 0.25 g sulphur charges are from USGS Open-File Report 02-223; and the 600 mg with 5.400 g lithium tetraborate is from USGS Bulletin 1823 chapter 5.source
- Carbon: 1350 degrees C, working range 0.05-50%, LOD 0.03%. Sulphur: 1350 degrees C, working range 0.05-35%, LOD 0.0004%, LLD 0.0007%, duplicate RSD 3%USGS combustion-infrared performance for total carbon and total sulphur in geological materials — the numbers behind acid-generation and carbonate assessments.source
- Sodium peroxide sinter at 450 degrees C for 55 elements; four-acid HCl-HNO3-HClO4-HF at low temperature for 42 elements with majors to 0.01% and As/Ag to 1 ppmTwo USGS digestion tiers side by side: the 450 degrees C sodium peroxide sinter package for 55 elements (USGS Open-File Report 2005-1450, linked below) and the 0.25 g four-acid 42-element package (USGS Open-File Report 2006-1070). Together they show why digestion choice changes the answer.source
How it is actually bought
Contract shapes and what they price
Laboratories publish a method-code price list and bill per sample: preparation is priced per sample by prep code, each analytical package is priced per sample, and overlimit or check work is a further per-sample charge, with tiered turnaround (standard versus priority) attracting a surcharge. Work is submitted in batches with a submittal form that specifies the prep and analysis codes, and the buyer — not the lab — decides the QA/QC insertion scheme, so if you do not instruct the lab to report standards, blanks and duplicates you will not get them. Consulting geologists are bought either on a day rate plus expenses and travel for field and logging work, or as a lump-sum deliverable for a defined report (a resource estimate, a technical report summary), typically with a named individual, a stated scope, a review step and a signature and consent clause; core-farm staff and logging crews are usually day rate plus accommodation and vehicle. Metallurgical test work is scoped as a programme of named tests on named composites and priced per test or as a lump sum per phase, with sample shipping, sample preparation and the head assay billed separately, and phases gated so the next batch of tests is only authorised after the previous results are read. A normal engagement is: sampling and QA/QC protocol agreed in writing, a lab chosen by checking its scope of accreditation for the exact methods and detection limits you need, a small pilot batch to test turnaround and precision, then production batches with monthly QA/QC reconciliation and a second lab retained for umpire work from the start rather than after a dispute.
Who regulates it
And what each one requires of this trade
- U.S. Securities and Exchange Commission — Regulation S-K subpart 1300 (17 CFR 229.1300–1305) — Any mineral resource or reserve a U.S. registrant discloses must rest on work by a 'qualified person' with at least five years of relevant experience who is a member or licensee in good standing of a recognised professional organisation, and the registrant must file a dated, signed technical report summary and obtain the qualified person's written consent.
- OSHA — Occupational Exposure to Hazardous Chemicals in Laboratories, 29 CFR 1910.1450 — Requires a lab to maintain a written Chemical Hygiene Plan reviewed annually, designate a qualified Chemical Hygiene Officer, provide hazard training, and monitor exposures with employee notification within 15 working days.
- OSHA — Lead standard, 29 CFR 1910.1025 — Directly binds fire assay laboratories, which handle litharge: an 8-hour PEL of 50 µg/m³, a 30 µg/m³ action level triggering monitoring at least every 6 months, blood-lead medical surveillance, and mandatory medical removal at a single result of 60 µg/100 g or a three-test average of 50 µg/100 g.
- MSHA — 30 CFR Part 46 site-specific hazard awareness training — Geologists, samplers and core-shed staff who are on mine property must receive site-specific hazard awareness training before being exposed to mine hazards, and contractors must train their own people (§§ 46.11, 46.12).
- State boards for the licensure of geologists (varies by state) — In states that regulate the practice of geology, only a state-licensed or registered Professional Geologist may sign geologic work for the public; whether licensure exists, what it is called and what it covers is set state by state through these boards.
The standards that apply
Ask which of these a firm works to
- ISO/IEC 17025:2017 — General requirements for the competence of testing and calibration laboratories (3rd edition, November 2017, current) — The accreditation standard for laboratory competence, impartiality and consistent operation; what matters commercially is not the certificate but the lab's scope of accreditation, which lists the specific methods and matrices it is accredited for.
- ASTM E1915-20 — Standard Test Methods for Analysis of Metal Bearing Ores and Related Materials for Carbon, Sulfur, and Acid-Base Characteristics — Seven test methods covering total and residual carbon and sulfur, HCl-insoluble species and acid neutralisation potential in ores, leach residues, tailings and waste rock, explicitly supporting acid-base accounting (ANP minus AGP = net calcium carbonate) — this is the standard behind acid rock drainage prediction.
- ASTM E2294-21 — Standard Practice for Proof Silver Corrections in Metal Bearing Ores, Concentrates, and Related Materials by Fire Assay Gravimetry — Maintained by subcommittee E01.02, it defines the proof-silver correction for silver loss in the fire assay process — the practice that matters when a silver assay settles a commercial transaction between buyer and seller.
- CRIRSCO International Reporting Template (June 2024 update) and the SME Guide for Reporting (2017) — The reporting codes that define Exploration Results, Mineral Resources and Mineral Reserves and require a Competent Person with a minimum of five years of relevant experience in the style of mineralisation or type of deposit (Clause 3.6); SME's 2017 Guide is the U.S. member code and SME advocated for what became SEC S-K 1300.
- ASTM D5079-25 — Standard Practices for Preserving and Transporting Rock Core Samples — Active standard covering preservation, transport, storage, cataloguing, retrieval and post-test disposition of rock core — the reference to cite in a core-farm or core-storage contract so that core remains a usable sample of record.
What to demand from a firm
Credentials worth checking before you sign
- The laboratory's ISO/IEC 17025 scope of accreditation (not just 'we are accredited') — Demand the actual scope document from the accreditation body's public directory and check that the specific method codes, matrices and reporting ranges you are buying appear on it; accreditation is method-by-method, so a lab can be accredited and still be unaccredited for your assay.
- State-licensed or registered Professional Geologist (varies by state) — Where the state regulates geology, the person signing your geologic work must be licensed by that state's board; verify the licence directly with the board rather than accepting letterhead, and remember a licence in one state does not authorise practice in another.
- Qualified Person status under SEC S-K 1300 — e.g. SME Registered Member — SME's Registered Member programme exists so members can meet the recognised-professional-organisation criteria, and requires a relevant degree, a minimum of 7 years professional experience with at least 3 in a position of responsibility, plus a state geologist licence, AIPG CPG, PE, or three Registered Member endorsements — but SME itself warns that Registered Member status alone does not make someone a Qualified Person for your particular deposit and activity.
- AIPG Certified Professional Geologist (CPG) — Requires a bachelor's degree or higher in the geological sciences with a minimum of 36 semester hours (54 quarter hours) of geology, 8 years of professional geological experience (7 with a master's, 5 with a PhD), and passage of a peer review of education, experience, competence and ethical conduct.
Where to find firms yourself
Public registers and member directories
- A2LA Directory of Accredited Organizations — Public searchable directory of A2LA-accredited laboratories filterable by accreditation programme (including ISO/IEC 17025 testing), field of testing (chemical, environmental, mechanical), country and state, plus keyword search across scopes, test methods and certificate numbers.
- ANAB Directory of Accredited Organizations — The other major U.S. laboratory accreditation body's public directory of accredited testing laboratories and their scopes, for cross-checking a lab that is not A2LA-accredited.
- ASBOG member board index (state boards of geology) — State-by-state index of the boards that license or register geologists, with each board's contact details — the authoritative route to verifying a consulting geologist's licence and to finding the state's public licensee register.
- SME Registered Member Directory — SME publishes a Registered Member directory, which exists partly to satisfy the S-K 1300 requirement that a recognised professional organisation provide a public list of members in good standing; the listing is sortable and searchable, though contact details require a login.
Numbers worth knowing
Each one carries its source
The minimum relevant experience, in the type of mineralisation and type of deposit and in the specific activity, for a 'qualified person' under SEC S-K 1300 — the floor for anyone signing a technical report summary.
sourceSME Registered Member experience requirement, alongside a relevant university degree and one of: state geologist licence, AIPG CPG, PE/PEng, PGeo, or three Registered Member endorsements.
sourceOSHA lead limits that a fire assay laboratory must meet, with air monitoring at least every 6 months above the action level and quarterly above the PEL — a real question to ask a prospective assay lab.
sourceThe ranges ASTM E1915-20 covers for ores, leach residues, tailings and waste rock — the working window for acid-base accounting work, so samples outside it need a different method.
sourceUSGS price for its geochemical and microanalytical reference materials (BCR-2, BHVO-2, BIR-1a, shales, granite, stream sediment and glass standards), which labs and buyers use as independent QA/QC control samples; note USGS has suspended new orders, so plan CRM supply ahead.
sourceHow this goes wrong
The specific traps, not general advice
- Accepting 'ISO 17025 accredited' at face value instead of pulling the lab's scope of accreditation from the accreditation body's public directory and confirming the exact method codes, matrices and detection limits are on it — accreditation is granted method by method, not to the building.
- Not specifying the QA/QC insertion scheme in the submittal instructions, so no certified reference materials, blanks or duplicates are inserted; the assays are then unauditable, a qualified person will not sign off on them, and the only fix is re-assaying from pulps that may no longer exist.
- Choosing a partial (aqua regia) digestion when the deposit hosts the metal in refractory minerals that a partial leach does not dissolve, and reporting the resulting low grades as real; the inverse error is paying for four-acid ICP-MS on samples that only needed a cheap screen.
- Sending everything to one laboratory with no umpire lab engaged, then having no independent basis to resolve a bias when the results are challenged — a second lab has to be lined up at the start of the programme, not after the argument.
- Treating core and pulps as disposable: no photography before splitting, no chain-of-custody record, no climate-controlled storage and no catalogue, so the samples of record cannot be re-examined and the whole dataset has to be regenerated by redrilling.
The vocabulary
Defined by someone who is not selling you anything
- Nugget effect
- The variance in an assay that comes from the physical distribution of the metal rather than from the analysis — when the metal occurs as sparse coarse grains, whether your subsample happened to contain one is largely chance. It is the reason two splits of the same crushed sample can return wildly different gold grades, and it cannot be fixed by a better instrument, only by a bigger or better-prepared sample.
- Detection limit
- The lowest concentration a method can report with confidence that it is really there and not blank noise. EPA's formal definition is 'the minimum measured concentration of a substance that can be reported with 99% confidence that the measured concentration is distinguishable from method blank results'. Results below it are reported as less-than values, not as zero.
- Over-limit / ore-grade re-assay
- A second analysis run when a sample exceeds the calibrated upper range of the routine method. The routine result is not wrong so much as off-scale; the ore-grade method uses a different dilution, a different finish, or a gravimetric determination. Any dataset with unexplained flat-topped high grades has an over-limit handling problem.
- Pulp
- The finely pulverised powder actually presented to the analytical instrument, typically a few hundred grams of material ground to about 85% passing 75 micrometres, from which the 30-50 g charge is scooped. Pulps are retained after analysis and are what gets sent for umpire assaying.
- Reject (coarse reject)
- The crushed material left over after the pulp was split out — coarser than a pulp and usually several kilograms. It is kept because it is the only remaining material that can be re-split to test whether the original subsampling was representative.
- Split
- A representative portion taken from a larger sample, and the act of taking it. Riffle splitters, rotary splitters and cone splitters exist because scooping from the top of a heap is not representative — heavy and fine particles segregate, and a scoop takes a biased sample of both.
- Assay tonne (assay ton)
- A sample mass chosen so that the arithmetic comes out clean: a weight such that 'each milligram of a noble metal in the sample is equivalent to one troy ounce in one avoirdupois ton (2000 lb) of ore'. In North America it is 29.167 g; where the 2240 lb long ton is used it is 32.667 g. The common 30 g fire assay charge is approximately one assay tonne.
- Grade
- The concentration of the metal or mineral in the rock. S-K 1300 does not define grade on its own; the phrase 'the concentration of metal or mineral in rock' appears as a parenthetical inside its definition of cut-off grade at 17 CFR 229.1300. Expressed as grams per tonne or troy ounces per short ton for precious metals, and as a percentage for base metals and bulk commodities.
- Cut-off grade
- The grade at which material stops being ore and becomes waste — SEC defines it as 'the grade that determines the destination of the material during mining'. It is an economic parameter, not a geological one, so it moves with metal price, costs and recovery, and a resource stated without its cut-off grade is not interpretable.
- Salting
- The fraudulent addition of metal to a sample, or the substitution of a richer sample, to make a property appear more valuable. Chain of custody, blind control samples, secure sample numbering and independent check assaying exist primarily because salting is a real and recurring failure mode in mineral exploration.
- Half core
- The half of a sawn drill core submitted for assay. The other half stays in the box so the interval can be re-logged, re-photographed and re-assayed later. Taking whole core doubles the sample mass — useful for nuggety gold — but destroys the ability to verify the result.
- Standard deviation of a CRM
- Every certified reference material is issued with a certified mean value and a standard deviation derived from a round-robin of laboratories. Control charts plot each insertion against that mean, with warning and action limits commonly drawn at two and three standard deviations; practice reviews note control limits are 'usually at plus/minus three standard deviations'.
- Partial versus total digestion
- A partial digestion (aqua regia, weak leaches) dissolves only the readily attacked minerals and reports low for anything locked in silicates or resistant oxides. A total digestion (fusion) dissolves everything. Four-acid sits between and is called 'near-total'. Results from different digestions are not interchangeable.
- Refractory minerals
- Minerals that resist acid attack and survive digestion intact, taking their contained elements with them — zircon, chromite, rutile, cassiterite, monazite, barite, spinel and tourmaline. EPA states plainly that 'a few refractory sample matrix compounds, such as TiO2, alumina, and other oxides may not be totally dissolved' and 'might sequester target analyte elements'.
- Cupellation
- The second stage of a fire assay: the lead button is heated in a porous bone-ash cup in an oxidising atmosphere, the lead oxidises to litharge and is absorbed into the cup, and the noble metals are left behind as a small bead. Gold survives this well; silver and palladium are partly lost into the cupel.
- Parting
- Dissolving the silver out of a gold-silver bead with nitric acid so the gold can be weighed alone. It only works if enough silver is present, which is why silver is deliberately added before cupellation, at a multiple of the fine gold present set by the bullion assay standard in use.
- Flux
- The reagent mixture a sample is fused with. In fire assay it is soda ash, litharge, silica, borax and a reductant, and its job is to make a fluid slag and produce a lead collector. In borate or peroxide fusion it is lithium tetraborate or sodium peroxide, and its job is to dissolve the silicate lattice outright.
- hard (half absolute relative difference)
- The standard precision statistic for duplicate pairs: the absolute difference between the two results divided by twice their mean, as a percentage. Duplicate performance is stated as the proportion of pairs falling within a band — for example '90 % +/- 10-25 % hard' for fine gold field duplicates.
Questions to ask before you sign
- What accreditation does the lab hold, and for which methods?
- What is your turnaround at present, and what is your queue?
- What standards, blanks and duplicates do you insert, and at what rate?
Where to next
Exploration & geophysics
Surveys, geochem, remote sensing and target generation
PreviousDrilling & boring
Core, RC, rotary, sonic and geotechnical drilling
Free listingWork in this trade?
List your business here at no cost. Every submission is read by a person before it goes up.
Every figure and requirement on this page is linked to the agency, standard or register it came from. Nothing here is legal advice, rules change, and a link is worth more than our summary of it — follow them.